<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Drinking Water Salinity Monitoring Products - Australian Scientific</title>
	<atom:link href="https://www.austscientific.com.au/product-tag/drinking-water-salinity-monitoring/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description></description>
	<lastBuildDate>Mon, 09 Feb 2026 23:55:07 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.austscientific.com.au/storage/2019/07/Aust-Scientific-150x150.png</url>
	<title>Drinking Water Salinity Monitoring Products - Australian Scientific</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Salt Meter Pocket Type – LAQUAtwin ION Salt-11</title>
		<link>https://www.austscientific.com.au/product/laquatwin-salt-11-compact-meter/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 07 Jul 2017 02:44:46 +0000</pubDate>
				<guid isPermaLink="false">https://www.austscientific.com.au//?post_type=product&#038;p=2608</guid>

					<description><![CDATA[<h6 style="text-align: center;"><strong>2 point calibration with temperature display<br />
</strong>Conversion of Conductivity Method<br />
<strong><span style="color: #ff0000;"><span style="color: #ff0000;">Usually Stocked</span><br />
</span><span style="color: #106840;">This equipment contains button batteries and is intended to be used in trades, professions or industries only.</span></strong></h6>
<p>The post <a href="https://www.austscientific.com.au/product/laquatwin-salt-11-compact-meter/">Salt Meter Pocket Type – LAQUAtwin ION Salt-11</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div></div>
<p>The only pocket meter that directly measures conductivity in 0.12ml sample and converts it into salinity or salt concentration. No need for a beaker to calibrate the meter or measure a sample. Just place few drops of the standard or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample.</p>
<ul>
<li>Minimum sample volume: 0.12ml</li>
<li>Salinity and temperature display</li>
<li>Up to 2 calibration points</li>
<li>Auto calibration</li>
<li>Auto standard recognition: 0.50 &amp; 5.00 % NaCl</li>
<li>Auto temperature compensation: 2%/ºC fixed</li>
<li>Temperature calibration: 5 to 40.0 ºC</li>
<li>2 Salinity curves: NaCl &amp; Seawater</li>
<li>Auto stable / auto hold measurement</li>
<li>Auto power off: 30 mins.</li>
<li>Low battery indicator</li>
<li>IP67 Rating dust &amp; waterproof</li>
<li>Replaceable sensor</li>
<li>400 Hours battery life: continuous use without backlight</li>
<li>Material: ABS epoxy body &amp; titanium coated with platinum black sensor</li>
<li>Display: custom (monochrome) digital LCD with backlight</li>
<li>Operating conditions: 5 to 40°C, 85% or less relative humidity</li>
<li>Warranty: 2 years &#8211; meter, 6 months &#8211; sensor</li>
<li>Packed in handy carrying case</li>
<li>Supplied with 0.5% &amp; 5.0% NaCl standards (14ml each), conditioning solution (4ml), 2 x CR2032 batteries, dropper, instruction and quick manuals</li>
</ul>
<div>
<p style="text-align: center;"><strong>This equipment contains button batteries and is not intended for general consumer use.<br />
</strong></p>
<p style="text-align: left;"><a ref="magnificPopup" href="https://www.austscientific.com.au/storage/2021/07/button-battery.jpg"><img decoding="async" class="wp-image-13814 alignleft" src="https://www.austscientific.com.au/storage/2021/07/button-battery-300x300.jpg" alt="" width="111" height="111" srcset="https://www.austscientific.com.au/storage/2021/07/button-battery-300x300.jpg 300w, https://www.austscientific.com.au/storage/2021/07/button-battery-150x150.jpg 150w, https://www.austscientific.com.au/storage/2021/07/button-battery-350x350.jpg 350w, https://www.austscientific.com.au/storage/2021/07/button-battery-600x600.jpg 600w, https://www.austscientific.com.au/storage/2021/07/button-battery-450x450.jpg 450w, https://www.austscientific.com.au/storage/2021/07/button-battery.jpg 1000w" sizes="(max-width: 111px) 100vw, 111px" /></a>(i)  the equipment is intended to be used in trades, professions or industries only;<br />
(ii)  the equipment is not intended for sale to the general public;<br />
(iii)  the equipment is not intended to be used where children are present;</p>
</div>
<p>&nbsp;</p>
<p>The post <a href="https://www.austscientific.com.au/product/laquatwin-salt-11-compact-meter/">Salt Meter Pocket Type – LAQUAtwin ION Salt-11</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Salt Meter Pocket Type – LAQUAtwin ION Salt-22</title>
		<link>https://www.austscientific.com.au/product/salt-22-laquatwin-compact-salt-meter/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 19 Sep 2014 01:59:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.austscientific.com.au//?post_type=product&#038;p=51</guid>

					<description><![CDATA[<h6 style="text-align: center;"><strong><span style="color: #000000;">(Ion Selective Electrode Method)</span></strong><br />
<strong><span style="color: #ff0000;">Usually Stocked<br />
</span></strong><span style="color: #106840;"><strong>This equipment contains button batteries and is intended to be used in trades, professions or industries only.</strong></span></h6>
<p>The post <a href="https://www.austscientific.com.au/product/salt-22-laquatwin-compact-salt-meter/">Salt Meter Pocket Type – LAQUAtwin ION Salt-22</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>This equipment contains button batteries and is not intended for general consumer use.<br />
</strong></p>
<p style="text-align: left;"><a ref="magnificPopup" href="https://www.austscientific.com.au/storage/2021/07/button-battery.jpg"><img decoding="async" class="wp-image-13814 alignleft" src="https://www.austscientific.com.au/storage/2021/07/button-battery-300x300.jpg" alt="" width="111" height="111" srcset="https://www.austscientific.com.au/storage/2021/07/button-battery-300x300.jpg 300w, https://www.austscientific.com.au/storage/2021/07/button-battery-150x150.jpg 150w, https://www.austscientific.com.au/storage/2021/07/button-battery-350x350.jpg 350w, https://www.austscientific.com.au/storage/2021/07/button-battery-600x600.jpg 600w, https://www.austscientific.com.au/storage/2021/07/button-battery-450x450.jpg 450w, https://www.austscientific.com.au/storage/2021/07/button-battery.jpg 1000w" sizes="(max-width: 111px) 100vw, 111px" /></a>(i)  the equipment is intended to be used in trades, professions or industries only;<br />
(ii)  the equipment is not intended for sale to the general public;<br />
(iii)  the equipment is not intended to be used where children are present;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The only compact meter to measure sodium ion concentration and calculate into salinity or NaCl salt concentration unlike the conductivity converted meters. Flat sensor technology and 60 years of sensor engineering realizes a reliable and direct measurement of a drop of the sample from 0.3mL.Unique sensor mechanism realizes direct measurement of solid, viscous, powder samples. Use sampling sheet (sold separately) to measure down to 0.05mL.</p>
<p>No need for a beaker to calibrate or measure. Just drop the standards and sample on the flat sensor, saves you time and minimizes wasting your precious sample.</p>
<p><strong>Applications include:</strong><br />
Soil and sap testing for improved agriculture; food testing*</p>
<p>* Detection of ions in water only; electrolytes in oils cannot be measured. Ion measurement can be affected by non-target ions.</p>
<h2>Functions</h2>
<ul>
<li>Autocalibration function recognizes standards and is user-selectable for either one- or two-point calibrations.</li>
<li>Auto range change</li>
<li>Temperature compensation</li>
<li>IP67 waterproof</li>
<li>Auto hold</li>
<li>Automatic power off （30 minutes）</li>
</ul>
<p>The post <a href="https://www.austscientific.com.au/product/salt-22-laquatwin-compact-salt-meter/">Salt Meter Pocket Type – LAQUAtwin ION Salt-22</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>