<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Turbidity Testing Solution Products - Australian Scientific</title>
	<atom:link href="https://www.austscientific.com.au/product-tag/turbidity-testing-solution/feed/" rel="self" type="application/rss+xml" />
	<link></link>
	<description></description>
	<lastBuildDate>Tue, 31 Mar 2026 04:41:59 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.austscientific.com.au/storage/2019/07/Aust-Scientific-150x150.png</url>
	<title>Turbidity Testing Solution Products - Australian Scientific</title>
	<link></link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Turbidity Standard 8NTU &#8211; 500ml</title>
		<link>https://www.austscientific.com.au/product/turbidity-standard-8ntu-500ml/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 20 Jan 2016 04:58:59 +0000</pubDate>
				<guid isPermaLink="false">https://www.austscientific.com.au//product/turbidity-standard-8ntu-500ml/</guid>

					<description><![CDATA[<h5><span style="color: #ff0000;">Usually Stocked</span></h5>
<p>The post <a href="https://www.austscientific.com.au/product/turbidity-standard-8ntu-500ml/">Turbidity Standard 8NTU &#8211; 500ml</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Formazin suspension designed for the calibration of turbidity meters. It is prepared following the procedure outlined in the 18th Edition (1992) of APHA, AWWA, and WEF Standard Methods for the Examination of Water and Wastewater – Method 2130 B (Nephelometric Method).</p>
<p>This solution is ideal for calibrating low-range turbidity on the HORIBA U-50 series.</p>
<p>The post <a href="https://www.austscientific.com.au/product/turbidity-standard-8ntu-500ml/">Turbidity Standard 8NTU &#8211; 500ml</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Turbidity Standard 80NTU &#8211; 500ml</title>
		<link>https://www.austscientific.com.au/product/turbidity-standard-80ntu-500ml/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 20 Jan 2016 05:04:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.austscientific.com.au//product/turbidity-standard-80ntu-500ml/</guid>

					<description><![CDATA[<h5><span style="color: #ff0000;">Usually Stocked</span></h5>
<p>The post <a href="https://www.austscientific.com.au/product/turbidity-standard-80ntu-500ml/">Turbidity Standard 80NTU &#8211; 500ml</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Formazin suspension designed for the calibration of turbidity meters. It is prepared following the procedure outlined in the 18th Edition (1992) of APHA, AWWA, and WEF Standard Methods for the Examination of Water and Wastewater – Method 2130 B (Nephelometric Method).</p>
<p>This solution is ideal for calibrating mid-range turbidity on the HORIBA U-50 series.</p>
<p>The post <a href="https://www.austscientific.com.au/product/turbidity-standard-80ntu-500ml/">Turbidity Standard 80NTU &#8211; 500ml</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Turbidity Standard 400NTU &#8211; 500ml</title>
		<link>https://www.austscientific.com.au/product/turbidity-standard-400ntu-500ml/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 20 Jan 2016 05:06:44 +0000</pubDate>
				<guid isPermaLink="false">https://www.austscientific.com.au//product/turbidity-standard-400ntu-500ml/</guid>

					<description><![CDATA[<h5><span style="color: #ff0000;">Usually Stocked</span></h5>
<p>The post <a href="https://www.austscientific.com.au/product/turbidity-standard-400ntu-500ml/">Turbidity Standard 400NTU &#8211; 500ml</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Formazin suspension designed for the calibration of turbidity meters. It is prepared following the procedure outlined in the 18th Edition (1992) of APHA, AWWA, and WEF Standard Methods for the Examination of Water and Wastewater – Method 2130 B (Nephelometric Method).</p>
<p>This solution is ideal for calibrating high-range turbidity on the HORIBA U-50 series.</p>
<p>The post <a href="https://www.austscientific.com.au/product/turbidity-standard-400ntu-500ml/">Turbidity Standard 400NTU &#8211; 500ml</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Turbidity Meter Kit – Portable TN400</title>
		<link>https://www.austscientific.com.au/product/tn400-portable-turbidity-meter-kit/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 08 May 2019 03:49:47 +0000</pubDate>
				<guid isPermaLink="false">https://www.austscientific.com.au//?post_type=product&#038;p=4247</guid>

					<description><![CDATA[<h5 style="text-align: center;"><span style="color: #000000;">ISO 7027 Compliant – Includes carry case and calibration solution</span></h5>
<h5 style="text-align: center;"><span style="color: #ff0000;">Usually Stocked</span></h5>
<p>The post <a href="https://www.austscientific.com.au/product/tn400-portable-turbidity-meter-kit/">Turbidity Meter Kit – Portable TN400</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The <strong>Apera Instruments TN400 Portable Turbidity Meter</strong>, Large Colored TFT display with graphic and text guides, Accuracy: ±1% or 0.02 NTU, whichever is greater</p>
<ul>
<li>Infrared light source — ISO7027 compliant</li>
<li>Easy and quick calibration</li>
<li>TFT Colored Screen (measurement mode, green in calibration) with graphic and text operation guides</li>
<li>U.S. EPA certified, non-toxic, easy-to-use polymer standard solutions</li>
<li>CE certified and comes with 2-Year Warranty</li>
</ul>
<p>The Apera Instruments TN400 Portable Turbidity Meter is built with an infrared light source, using ISO7207 compliant nephelometric method (90<strong>°</strong>), equipped with a large TFT colored screen, designed for reliable turbidity measurements from 0 to 1000 NTU in various applications both in-field and in-lab e.g. environmental monitoring, water treatment, beverage making, etc.</p>
<p>The test kit comes with 4 vials of<sup> </sup>high-molecular polymer turbidity standard solutions (0.02 NTU, 20.0 NTU, 100 NTU, 800 NTU), an EPA approved primary standard for calibration of turbidity sensors that is safe, non-toxic and disposable. It is NIST traceable to particle size/distribution and optical density, and its inherent stability means it does not settle from suspension.</p>
<p>The standards have a guaranteed one-year shelf life even if you’ve opened the bottle and happened not to have recapped it tightly. The convenient submicron polymer suspensions are non-toxic primary calibration standards approved by the US EPA for drinking water analysis for turbidity.</p>
<p>The meter is CE certified and comes with a 2-year warranty.</p>
<p>The post <a href="https://www.austscientific.com.au/product/tn400-portable-turbidity-meter-kit/">Turbidity Meter Kit – Portable TN400</a> appeared first on <a href="https://www.austscientific.com.au">Australian Scientific</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
