Compact Meters

Horiba Compact MetersCompact Meters offering accurate measurement from only a single drop to Horiba original flat sensor.

LAQUAtwin’s easy, reliable and quick measurement of 7 parameters brings new dimension to your water quality testing.

HORIBA introduces LAQUAtwin compact water quality meter, incorporating 60 years of water quality analyzer research and manufacturing technology into a pen sized, simple design. Select from seven water quality parameters such as pH , conductivity, various ions (Na+, K+, NO3-, Ca2+) and salinity that suits your purpose. Bring LAQUAtwin with you wherever and whenever you want to. It is your “lab-in-the-field.”

  • Accurate reading from only a single drop, in a few seconds. Furthermore, select measurement method depending on your situation and sample. (Drops, Immersion, Scoop, Wipe,Solid samples, Powders, Paper, textiles and films)
  • pH, conductivity, ions and salinity. 7 parameters, 11 models.
  • Calibrate and measure at the touch of a button – the Smiley face will tell you when the result can be read.
  • LAQUAtwin is fully waterproof and dustproof (IP67).
  • Carry case comes standard for handy portability.

Calibration solutions included for each model.

For all models, please download this brochure.

Models & Details

pH 11, pH 22, pH 33 LAQUAtwin Compact pH Meter

Horiba Compact Meters

Accurate pH measurements in a few seconds, from a single drop.*

Water pH varies in different environments, and a slight change can often have a major effect.

Whether you need to keep the pH of an aquarium within tight limits, are checking for the acidity of rain water or for the quality of meat and fish products, LAQUAtwin compact pH meters are ideal for you. No matter where and when you need to test.

Applications include:
Fresh water testing (rain, rivers, lakes, hot springs); aquaria; drainage treatment solutions; soil testing for improved agriculture; fermentation and brewing; food freshness testing; research laboratories; QC of medical supplies and cosmetics; preventative dentistry; school education, etc.

* Minimum volume required – 0.1 mL (0.05 mL when using the HORIBA sampling sheet. Additional sampling sheets available from HORIBA as 100pc/box)

Functions

  • Autocalibration function recognizes standards.
  • Temperature compensation
  • IP67 waterproof
  • Auto hold
  • Automatic power off(30 minutes)
  • 2, 3, or 5 calibration points, depending on model
  • Model pH33 displays temperature
  • All models supplied with calibration solution (pH 4 & pH 7)

EC-11, EC-22, EC-33 LAQUAtwin Compact Conductivity meter

Horiba Compact MetersFlat sensor technology and 60 years of sensor engineering realizes a reliable and direct measurement of a drop of the sample from 0.12mL. No need for a beaker to calibrate or measure. Just drop the standards and sample on the flat sensor, saves you time and minimize wasting your precious sample.Conductivity readings can be converted into salinity and TDS.

Three models to choose from:

  • EC-11 range 0-19.99mS/cm
  • EC-22 range 0-199mS/cm
  • EC-33 range 0-199mS/cm and 0-9990ppm
Applications include:
  • Fresh water testing (rain, rivers, lakes, hot springs); aquaria; soil
  • testing for improved agriculture and analysis of salt water damage;
  • analysis of surface cleanliness prior to coating; and improved paint adhesion.

B-722 LAQUAtwin Compact Sodium Ion Meter

Horiba Compact MetersOnly compact meter for a quick measurement of sodium ion using ion selective membrane.Flat sensor technology and 60 years of sensor engineering realizes a reliable and direct measurement of a drop of the sample from 0.3mL. No need for a beaker to calibrate or measure. Just drop the standards and sample on the flat sensor, saves you time and minimize wasting your precious sample.

Applications include:
  • Plant sap testing
  • Health management;
  • food quality control;
  • environmental measurement;
  • salt water damage testing.

Note: Ion measurement can be affected by non-target ions (see brochure for details). Detection of ion in water only; electrolytes in oils cannot be measured.

B-731 LAQUAtwin Compact Potassium Ion Meter

Horiba Compact MetersOnly compact meter for a quick measurement of potassium ion using ion selective membrane.Flat sensor technology and 60 years of sensor engineering realizes a reliable and direct measurement of a drop of the sample from 0.3mL. No need for a beaker to calibrate or measure. Just drop the standards and sample on the flat sensor, saves you time and minimize wasting your precious sample.

Applications include:
  • Plant sap testing;
  • Soil testing ( pretreatment required);
  • food quality control;
  • cultivation management;
  • health management
Note:  Ion measurement can be affected by non-target ions (see brochure for details). Detection of ion in water only; electrolytes in oils cannot be measured.

B-741/742/743 LAQUAtwin Compact Nitrate Meter

Horiba Compact MetersOnly compact meter for a quick measurement of nitrate ion using ion selective membrane.Flat sensor technology and 60 years of sensor engineering realizes a reliable and direct measurement of a drop of the sample from 0.3mL. No need for a beaker to calibrate or measure. Just drop the standards and sample on the flat sensor, saves you time and minimize wasting your precious sample.

Applications include:
  • Plant sap testing;
  • Soil testing (pretreatment required);
  • food quality control;
  • cultivation management;
  • food quality control;
  • growth management of crops.
Note: Ion measurement can be affected by non-target ions (see the glossary for details). Detection of ion in water only; electrolytes in oils cannot be measured.

B-751 LAQUAtwin Compact Calcium Ion Meter

Horiba Compact MetersOnly compact meter for a quick measurement of calcium ion using ion selective membrane.Flat sensor technology and 60 years of sensor engineering realizes a reliable and direct measurement of a drop of the sample from 0.3mL. No need for a beaker to calibrate or measure. Just drop the standards and sample on the flat sensor, saves you time and minimize wasting your precious sample.

Applications include:
  • Plant sap testing;
  • Soil testing (pretreatment required);
  • food quality control;
  • cultivation management;
  • health management;
  • breeding water of coral;
  • water hardness measurement
 Note: A sample pretreatment may be needed for measurement for total calcium concentration. Ion measurement can be affected by non-target ions (see the glossary for details). Detection of ion in water only; electrolytes in oils cannot be measured

B-721 LAQUAtwin Compact Salt Meter

Horiba Compact MetersOnly compact meter to measure sodium ion to calculate into NaCl based salt concentration unlike the conductivity converted meters.

Applications include:

  • Health management;
  • food quality control;
  • dietary instruction
Note: Detection of salt in water only; electrolytes in oils cannot be measured.

LAQUAtwin Salt-11 Compact Meter

Salt-11meter_4The only pocket meter that directly measures conductivity in 0.12ml sample and converts it into salinity or salt concentration. No need for a beaker to calibrate the meter or measure a sample. Just place few drops of the standard or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample.

  • Minimum sample volume: 0.12ml
  • Salinity and temperature display
  • Up to 2 calibration points
  • Auto calibration
  • Auto standard recognition: 0.50 & 5.00 % NaCl
  • Auto temperature compensation: 2%/ºC fixed
  • Temperature calibration: 5 to 40.0 ºC
  • 2 Salinity curves: NaCl & Seawater
  • Auto stable / auto hold measurement
  • Auto power off: 30 mins.
  • Low battery indicator
  • IP67 Rating dust & waterproof
  • Replaceable sensor
  • 400 Hours battery life: continuous use without backlight
  • Material: ABS epoxy body & titanium coated with platinum black sensor
  • Display: custom (monochrome) digital LCD with backlight
  • Operating conditions: 5 to 40°C, 85% or less relative humidity
  • Warranty: 2 years – meter, 6 months – sensor
  • Packed in handy carrying case
  • Supplied with 0.5% & 5.0% NaCl standards (14ml each), conditioning solution (4ml), 2 x CR2032 batteries, dropper, instruction and quick manuals

 

test-meters-banner

Latest News

Location

Contacts

11 McDougall Street
Kotara, NSW, 2289
Free Call: 02 4956 2299

e. sales@austscientific.com.au