Turbidity Meters

Turbidity Meters – Portable  (Turbidimeters)

Turbidity Meters

TN100-IR Portable Turbidimeter (waterproof)

The microprocessor-based waterproof TN100 meter is an easy-to-use turbidimeter that meets the rigour of rugged field applications. It is a “must -have” for anyone monitoring turbidity on the go.

Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).

Details:

  • IP67 Waterproof and Dustproof – Cleaning and maintenance is simple. It floats!
  • Automatic Push-Button Calibration (4 points) for unprecedented full-range accuracy
  • Sturdy Carrying Kit complete with 4 calibration standards, 3 empty cuvettes, batteries and comprehensive instruction manual
  • Power-saving feature allows over 1200 measurements to be taken with a single set of AAA alkaline batteries
  • Large Easy-to-Read Display for optimum viewing of measurements with user-friendly message codes for easy troubleshooting
  • Meets Performance Criteria as specified by ISO 1727 (DIN EN 27027) method
  • The microprocessor-based waterproof TN100 meter is an easy-to-use turbid-meter that meets the rigor of rugged field applications. It is a “must -have” for anyone monitoring turbidity on the go. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).

Specifications:

Product CodeEC-TN100IR
Principle of OperationNephelometric non-ratio (conformance to
ISO 7027 and DIN EN 27027)
Turbidity Range0 to 1000 NTU
Resolution0.01 NTU (0 to 19.9 NTU)
0.1 NTU (20.0 to 99.9 NTU)
1 NTU (100 to 1000 NTU)
Accuracy± 2% of reading ± 1 LSD for 0 to 500 NTU
± 3% of reading ± 1 LSD for 501 to1000 NTU
Repeatability± 1% of reading or ± 0.01 NTU
No. of Calibration Points4 points (automatic)
Response Time6 seconds for full step change
Calibration Standards0.02 NTU; 20.0 NTU; 100 NTU; 800 NTU
StandardisationEPA-approved polymer-based primary standards
Light Source Life> 1,000,000 tests
Light SourceInfrared-emitting diode (850nm wavelength)
Special FunctionsAuto-Ranging; Self-diagnostic
Power Requirements4 x 1.4V batteries, > 200 hours

Download Brochure

TN400 Portable Turbidity Meter Kit

 

The Apera Instruments TN400 Portable Turbidity Meter, Large Colored TFT display with graphic and text guides, Accuracy: ±1% or 0.02 NTU, whichever is greater

  • Infrared light source — ISO7027 compliant
  • Easy and quick calibration
  • TFT Colored Screen (measurement mode, green in calibration) with graphic and text operation guides
  • U.S. EPA certified, non-toxic, easy-to-use polymer standard solutions
  • CE certified and comes with 2-Year Warranty

The Apera Instruments TN400 Portable Turbidity Meter is built with an infrared light source, using ISO7207 compliant nephelometric method (90°), equipped with a large TFT colored screen, designed for reliable turbidity measurements from 0 to 1000 NTU in various applications both in-field and in-lab e.g. environmental monitoring, water treatment, beverage making, etc.

The test kit comes with 4 vials of high-molecular polymer turbidity standard solutions (0.02 NTU, 20.0 NTU, 100 NTU, 800 NTU), an EPA approved primary standard for calibration of turbidity sensors that is safe, non-toxic and disposable. It is NIST traceable to particle size/distribution and optical density, and its inherent stability means it does not settle from suspension.

The standards have a guaranteed one-year shelf life even if you’ve opened the bottle and happened not to have recapped it tightly. The convenient submicron polymer suspensions are non-toxic primary calibration standards approved by the US EPA for drinking water analysis for turbidity.

The meter is CE certified and comes with a 2-year warranty.

Specifications:

Measuring Method ISO 7027 compliant nephelometric Method(90°)
Measuring Range0 ~ 1000 NTU, automatic range selection: 0.01~19.99 NTU, 20.0~99.9 NTU, 100~1000 NTU.
Resolution0.01 / 0.1 / 1 NTU
Indication Error≤ ±2 % of reading±stray light
Repeatability≤ ± 1% of reading or 0.02 NTU, subject to whichever is greater
Calibration Standards0.02 NTU, 20.0 NTU , 100 NTU, 800 NTU(Polymer)
Light SourceInfrared-emitting diode(850nm wavelength)
DetectorSilicon photovoltaic
DisplayTFT Color screen
Sample VialsΦ25×60 mm, high borosilicate glass with screw cap
Sample Volume18 ml
Operating Temp. Range0~50℃
Power Supply4x “AA” Alkaline Batteries
IP RatingIP67

Download User Manual