Turbidity Meters

Turbidity Meters – Portable  (Turbidimeters)

Turbidity Meters

TN100-IR Portable Turbidimeter (waterproof)

The microprocessor-based waterproof TN100 meter is an easy-to-use turbidimeter that meets the rigour of rugged field applications. It is a “must -have” for anyone monitoring turbidity on the go.

Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).

Details:

  • IP67 Waterproof and Dustproof – Cleaning and maintenance is simple. It floats!
  • Automatic Push-Button Calibration (4 points) for unprecedented full-range accuracy
  • Sturdy Carrying Kit complete with 4 calibration standards, 3 empty cuvettes, batteries and comprehensive instruction manual
  • Power-saving feature allows over 1200 measurements to be taken with a single set of AAA alkaline batteries
  • Large Easy-to-Read Display for optimum viewing of measurements with user-friendly message codes for easy troubleshooting
  • Meets Performance Criteria as specified by ISO 1727 (DIN EN 27027) method
  • The microprocessor-based waterproof TN100 meter is an easy-to-use turbid-meter that meets the rigor of rugged field applications. It is a “must -have” for anyone monitoring turbidity on the go. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).

Specifications:

Product CodeEC-TN100IR
Principle of OperationNephelometric non-ratio (conformance to
ISO 7027 and DIN EN 27027)
Turbidity Range0 to 1000 NTU
Resolution0.01 NTU (0 to 19.9 NTU)
0.1 NTU (20.0 to 99.9 NTU)
1 NTU (100 to 1000 NTU)
Accuracy± 2% of reading ± 1 LSD for 0 to 500 NTU
± 3% of reading ± 1 LSD for 501 to1000 NTU
Repeatability± 1% of reading or ± 0.01 NTU
No. of Calibration Points4 points (automatic)
Response Time6 seconds for full step change
Calibration Standards0.02 NTU; 20.0 NTU; 100 NTU; 800 NTU
StandardisationEPA-approved polymer-based primary standards
Light Source Life> 1,000,000 tests
Light SourceInfrared-emitting diode (850nm wavelength)
Special FunctionsAuto-Ranging; Self-diagnostic
Power Requirements4 x 1.4V batteries, > 200 hours

Download Brochure

TN50 Portable Turbidimeter (waterproof)

Rugged and dependable for both lab and field use. Includes everything needed for lab or field measurements. Supplied complete with USEPA recognised calibration solns and carry case.

Features easy-to-use functions — automatic calibration with progress bar, on-screen status and instruction, low-battery indication, and automatic power off.

The large color TFT display uses a blue background in measurement mode and green background in calibration mode to minimise user errors.

Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units). Please check below specs for resolution in higher ranges

Specifications:

Measuring Method ISO 7027 compliant nephelometric Method(90°)
Measuring Range0 ~ 1000 NTU, automatic range selection: 0.01~19.99 NTU, 20.0~99.9 NTU, 100~1000 NTU.
Resolution0.01 / 0.1 / 1 NTU
Indication Error≤ ±2 % of reading±stray light
Repeatability≤ ± 1% of reading or 0.02 NTU, subject to whichever is greater
Calibration Standards0.02 NTU, 20.0 NTU , 100 NTU, 800 NTU(Polymer)
Light SourceInfrared-emitting diode(850nm wavelength)
DetectorSilicon photovoltaic
DisplayTFT Color screen
Sample VialsΦ25×60 mm, high borosilicate glass with screw cap
Sample Volume18 ml
Operating Temp. Range0~50℃
Power Supply4x “AA” Alkaline Batteries
IP RatingIP67

Download Brochure